BZKCG - WOOD'S METAL FUSIBLE STICKS

  • MSDS: BZKCG
  • Manufacturer: SARGENT WELCH SCIENTIFIC CO
  • Product Name: WOOD'S METAL FUSIBLE STICKS
  • National Stock Number: 6810-00N064191
Product Identification

Product ID:WOOD'S METAL FUSIBLE STICKS
MSDS Date:04/28/1986
FSC:6810
NIIN:00N064191
MSDS Number: BZKCG

Responsible Party
SARGENT-WELCH SCIENTIFIC CO
7300 NORTH LINDER AVE
SKOKIE, IL 60077
US

Emergency Phone: 312-677-0600

Info Phone: 312-677-0600

Cage: 64484

Contractor
SARGENT-WELCH SCIENTIFIC CO
1026 SKOKIE, IL 60076 US

Telephone: 312-267-5300

Cage: 64484

Ingredients

BISMUTH

CAS: 7440-69-9

RTECS: EB2600000

Fraction By Weight: 50%

OSHA PEL 15 MG/M3 TDUST

ACGIH TLV: 10 MG/M3


LEAD (SARA 313) (CERCLA)

CAS: 7439-92-1

RTECS: OF7525000

Fraction By Weight: 25%

OSHA PEL SEE 1910.1025

ACGIH TLV: 0.15MG/M3 DUST

EPA Report Quantity: 1 LB

DOT Report Quantity: 1 LB


TIN

CAS: 7440-31-5

RTECS: XP7320000

Fraction By Weight: 12.5%

OSHA PEL 2 MG/M3

ACGIH TLV: 2 MG/M3


CADMIUM OXIDE (SARA 302/313) (CERCLA)

CAS: 1306-19-0

RTECS: EV1925000

Fraction By Weight: 12.5%

OSHA PEL 0.2 MG (CD)/M3 DUST

ACGIH TLV: 0.01 MG(CD)/M3

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:YES IARC:YES OSHA:NO
Health Hazards Acute and Chronic:ACUTE: INHAL OF DUST/FUMES MAY CAUSE
RESP IRRIT, LUNG INJURY (EMPHYSEMA) & KIDNEY DISFUNCTION. CHRONIC:
LEAD APPEARS ON THE NAVY LISTING OF OCCUP CHEM REPRODUCTIVE HAZ.
SEEK CONSULTATION FROM APPROP H LTH PROFESSIONALS CONCERNING LATEST
HAZLIST INFO & SAFE HNDLG & EXPOS INFO .
Explanation of Carcinogenicity:CADMIUM OXIDE: IARC MONOGRAPHS, ON THE
EVALUATION OF CARCINOGENIC RISK OF CHEMICALS TO MAN, VOL 58, PG
119, (SUP DAT)
Effects of Overexposure:SEE HEALTH HAZARDS.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

First Aid

First Aid:INHALATION: IF THERE IS KNOWN EXPOS TO FUMES/DUST/IF SYMP OF
COUGH, CHEST TIGHTNESS/OR RESP DISTRESS APPEARS AFTER POSS EXPOS,
PLACE PATIENT AT BED REST & SEEK MED ATTN. KEEP PATIENT UNDER
OBSERVATION FOR 48 HRS. EYES: FLUSH W/POTABLE WATER FOR AT LEAST
15 MIN. SEE MD . SKIN: FLUSH W/COPIOUS AMTS OF WATER. SEE MD .
INGEST: CALL MD IMMED .

Fire Fighting

Extinguishing Media:USE MEDIA SUITABLE FOR SURROUNDING FIRE.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED SCBA & FULL
PROTECTIVE EQUIPMENT .
Unusual Fire/Explosion Hazard:AT EXTREME TEMPERATURES, TOXIC FUMES OF
LEAD AND CADMIUM OXIDE MAY BE EVOLVED.

Accidental Release

Spill Release Procedures:GATHER UP SPILLED MATERIAL AND PLACE IN A
SEALED CONTAINER TO BE RECYCLED OR FOR DISPOSAL IN AN APPROVED
LANDFILL.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:STORE IN A TIGHTLY CLOSED CONTAINER.
Other Precautions:NONE SPECIFIED BY MANUFACTURER.

Exposure Controls

Respiratory Protection:USE NIOSH/MSHA APPROVED RESPIRATOR IF CREATING
DUST OR FUMES.
Ventilation:LOCAL EXHAUST WHEN CREATING DUST AND FUMES.
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:ANSI APPRVD CHEM WORKERS GOGGS .
Other Protective Equipment:EMERGENCY EYEWASH & DELUGE SHOWER MEETING
ANSI DESIGN CRITERIA .
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
CARCIN EXPLAN: 1993: GROUP 1. NTP 7TH ANNUAL REPORT ON CARCINOGENS,
1994: ANTICIPATED TO BE CARCINOGEN. ANIMAL: LUNG.

Chemical Properties

Solubility in Water:INSOLUBLE
Appearance and Odor:GRAY METALLIC, ODORLESS

Stability

Stability Indicator/Materials to Avoid:YES
NONE.
Stability Condition to Avoid:HIGH TEMPERATURES.
Hazardous Decomposition Products:AT RED HOT TEMPERATURE, LEAD FUMES AND
CADMIUM OXIDE FUMES MAY BE EVOLVED.

Disposal

Waste Disposal Methods:THIS MATERIAL HAS RECLAIMATION VALUE. IF UNABLE
TO RECYCLE, DISPOSAL IN ACCORDANCE WITH ALL APPLICABLE FEDERAL,
STATE, AND LOCAL ENVIRONMENTAL REGULATIONS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.